Rockwool HT700 (High temperature board)

Product Description

Rockwool HT700 is a strong, rigid board.

Applications

Rockwool HT700 is developed for the thermal and acoustic insulation of constructions where higher temperatures and/or mechanical loads (e.g. vibrations) occur.

Advantages

• Excellent thermal and acoustic insulation
• Suitable for high temperature applications
• Retains shape
• Long lasting
• Rapid return on investment

Thermal conductivity

PerformanceTemperatureValueUnit of measureStandardStandard
t°m (°C)500.039λ (W/mK)EN 12667ASTM C177
t°m (°C)1000.044λ (W/mK)EN 12667ASTM C177
t°m (°C)1500.05 λ (W/mK)EN 12667ASTM C177
t°m (°C)2000.057λ (W/mK)EN 12667ASTM C177
t°m (°C)2500.065λ (W/mK)EN 12667ASTM C177
t°m (°C)3000.075λ (W/mK)EN 12667ASTM C177
t°m (°C)3500.087λ (W/mK)EN 12667ASTM C177
t°m (°F)1000.267λ (BTU.in/ft².h.°F)EN 12667ASTM C177
t°m (°F)2000.298λ (BTU.in/ft².h.°F)EN 12667ASTM C177
t°m (°F)3000.342λ (BTU.in/ft².h.°F)EN 12667ASTM C177
t°m (°F)4000.398λ (BTU.in/ft².h.°F)EN 12667ASTM C177
t°m (°F)5000.467λ (BTU.in/ft².h.°F) EN 12667ASTM C177
t°m (°F)6000.548λ (BTU.in/ft².h.°F)EN 12667ASTM C177
t°m (°F)7000.641λ (BTU.in/ft².h.°F)EN 12667ASTM C177

 

Technical properties and standards
PropertyPerformanceStandard
Maximum Service Temperature 700°C  (1292 F°)  EN 14706
  750°C  (1382 F°)  ASTM C411
Reaction to fire A1EN 13501-1
  Surface burning characteristics: Flame spread=passed, Smoke development=passedASTM E84 (UL 723)
Water absorptionWater absorption   < 1 kg/m² 
  Water vapour absorption (vapor sorption)   ± 0.02%vol  ASTM C1104/C1104M
Water leachable chloride contentConforms to the stainless steel corrosion specification as per ASTM test methods C692 and C871ASTM C795
Nominal density145 kg/m³  (9.0  lb/ft) 
Water vapour resistance factorμ =   1.0EN 12086
Compliance Rockwool (RW) slabs for thermal insulation of equipmentCINI 2.2.01
  Standard specification for mineral fibre block and board thermal insulation, type IA,IB, II, III, IVA, IVBASTM C612-04

Dimensions

Thickness mmLength mmWidth mmM2 pr. 40ft HC Packaging m2/pack
30100060021173.6
40100060016383
50100060013102.4
60100060010581.8